Low temperature Chamber for Impact Specimen

The series is designed according to Charpy notch Impact Test Method for Metal Material, and adopts compressor cooling technology. It utilizes the heat balance principle and cycle stirring method to realize the constant temperature cooling to impact specimen with the reliable performance. Digital display, automatic control temperature, and it is the ideal equipment for cooling and keeping temperature to impact specimen.
Model DWC-40 DWC-60 DWC-80 DWC-100
Temperature range +30~-40° +30~-60° +30~-80° +30~-100°
Temperature Control Accuracy ±0.5°
Effective working space 120×120×80mm
Specimen dimension 10×10×55mm
Specimen quantity More than 60 pcs
Temperature dropping speed +30°C~0°C 1.2°C/min +30°C~0°C 2°C/min +30°C~0°C 2°C/min +30°C~0°C 2°C/min
0°c~-20°C 0.8°C/min 0°c~-20°C 1.5°C/min 0°c~-20°C 1.5°C/min 0°c~-20°C 1.5°C/min
-20°C~-40°C 0.5°C/min -20°C~-40°C 1.0°C/min -20°C~-60°C 1.0°C/min -20°C~-40°C 1.0°C/min
-40°C~-60°C 0.7°C/min -60°C~-80°C 0.7°C/min -60°C~-100°C 0.7°C/min
Dimensions(mm) 800×510×480 800×510×480 800×510×480 800×510×480
Mode of refrigeration Compressor refrigeration
Cooling Medium Ethanol or other unfrozen liquid
 

Canadian Support

Technical assistance with equipment selection

Warranty Included

Manufacturer warranties on all equipment

Installation & Training

On-site or installation and hands-on training

Technical Specifications

Model GenChamber
Range of Control Temperature Low temperature: +30℃ to -80℃ (ambient temperature ≤ 25°C) High temperature: +30℃ to 100℃ (ambient temperature ≤ 25°C)
Temperature Control Accuracy Low temperature: ≤ ±0.5°C High temperature: < ±1°C
Display Resolution 0.1°C
Cooling Speed +30°C to 0°C: approx. 2°C/min 0°C to -20°C: approx. 1.5°C/min -20°C to -60°C: approx. 1°C/min -60°C to -80°C: approx. 0.7°C/min
Heating Speed +20°C to +50°C: approx. 2°C/min +50°C to +100°C: approx. 3°C/min
Working Area (L × W × H) Low Temperature Chamber: 5.9 × 5.5 × 4.7 in (150 × 140 × 120 mm) High Temperature Chamber: 5.9 × 5.5 × 4.7 in (150 × 140 × 120 mm)
Specimen Capacity 60–120 specimens (Standard size: 10 × 10 × 55 mm)
Outer Dimensions (L × W × H) 25.6 × 20.0 × 29.9 in (650 × 510 × 760 mm)
Timer 1 to 99 minutes, 1-second resolution
Cooling Medium Cooling chamber: Ethyl alcohol (≥ 99.5% purity recommended) Heating chamber: Air
Stirring Motor Power 23 W
Power Supply Single-phase, 110 V, 60 Hz, 2.5 kW

Need help selecting the right configuration?

Our application specialists are here to help you choosing the best solution for your materials and workflow.


    QMN Equipment Support

    Talk to an expert

    Get expert advice on models, accessories and standards.

    Why Buy From QMN Equipment?

    Equipment selected by testing professionals. Backed by CMH MetLabs expertise in:

    Hardness Testing

    Hardness Testing

    Brinell, Rockwell and Vickers and more

    Tensile testing

    Tensile Testing

    Universal Testing Machines

    Metallography

    Metallography

    Sample Preparation and Analysis

    NDT Inpection

    NDT Inspection

    UT, PT, MT, RT Solutions

    Failure Analysis

    Failure Analysis

    Expert Analysis and Reporting

    Backed by CMH Metlabs

    Accredited by

    CALA_Accred_Symbol_Colour

    Our in-house laboratory ensures you get the right equipment.

    Trusted by Manufacturers and Laboratories across Canada

    Manufacturig Companies

    Metallurgical Laboratories

    Heat Treatment Facilities

    Quality Control Departments

    Aerospace and Automotives

    Inspection and Testing Organizations