QE-DVH50 Digital Macro-Vickers Hardness Tester
The QE-DVH50 is a digital bench hardness tester for Vickers testing from HV1 to HV50. It combines automatic loading, dwell and unloading with a digital measuring eyepiece and direct hardness calculation.
It is designed for metals, heat-treated components, hardened layers, weld sections, precision parts and suitably prepared coating cross-sections.
Key Specifications
| Parameter | Specification |
|---|---|
| Test method | Vickers |
| Test forces | 1, 2, 2.5, 3, 5, 10, 20, 30 and 50 kgf |
| Force range | 9.807–490.3 N |
| Hardness range | 1–2967 HV |
| Loading cycle | Automatic loading, dwell and unloading |
| Turret | Manual indenter/objective switching |
| Magnification | 100× and 200× |
| Measuring increment | 0.125 µm at 200× |
| Dwell time | 0–60 seconds |
| Maximum specimen height | Approximately 160–170 mm |
| Throat depth | Approximately 130 mm |
| Dimensions | Approximately 535 × 225 × 630 mm |
| Weight | Approximately 50 kg |
The configuration was developed from the current QMN product listing and verified against comparable current 1–50 kgf digital macro-Vickers systems.
Canadian Support
Technical assistance with equipment selection
Warranty Included
Manufacturer warranties on all equipment
Installation & Training
On-site or installation and hands-on training
Technical Specifications
| Parameter | QE-DVH50 Specification |
|---|---|
| Model | QE-DVH50 |
| Machine type | Digital macro-Vickers bench hardness tester |
| Test method | Vickers indentation hardness |
| Test-force range | 1–50 kgf |
| Test forces | 1, 2, 2.5, 3, 5, 10, 20, 30 and 50 kgf |
| Test-force values | 9.807, 19.61, 24.52, 29.42, 49.03, 98.07, 196.1, 294.2 and 490.3 N |
| Supported Vickers scales | HV1, HV2, HV2.5, HV3, HV5, HV10, HV20, HV30 and HV50 |
| Hardness measuring range | 1–2967 HV |
| Test-force application | Automatic loading, dwell and unloading |
| Force selection | Manual selection according to the configured force system |
| Turret type | Manual indenter/objective switching |
| Indenter | 136° Vickers diamond pyramid |
| Optical measurement | Digital measuring eyepiece |
| Total magnification | 100× and 200× |
| Minimum measuring increment | 0.125 µm at 200× |
| Dwell-time range | 0–60 seconds |
| Hardness calculation | Automatic calculation from measured indentation diagonals |
| Displayed parameters | Test force, diagonal length, dwell time, test count and hardness result |
| Specimen stage | Elevating anvil table |
| Maximum specimen height | Approximately 160–170 mm, configuration-dependent |
| Throat depth | Approximately 130 mm |
| Standard anvils | Large flat, small flat and V-shaped anvils |
| Standard data output | Configuration-dependent |
| Optional data output | Mini-printer and RS-232 interface |
| Optional imaging system | CCD camera and computer-assisted indentation measurement |
| Typical overall dimensions | Approximately 535 × 225 × 630 mm |
| Power supply | 110 V, 60 Hz |
| Operating environment | Stable laboratory environment, free from vibration and corrosive vapours |
| Warranty | 12 months |
Applicable Standards
- ASTM E92 — Vickers and Knoop hardness
- ASTM E384 — applicable microindentation procedures
- ISO 6507-1:2023 — Vickers test method
- ISO 6507-2 — machine verification
- ISO 6507-3 — reference-block calibration
- ASTM E140 and ISO 18265 — hardness conversions
ISO 6507-1:2023 applies to Vickers impressions with diagonal lengths between 0.020 and 1.400 mm. ASTM E92 covers Vickers forces across a broader 1 gf–120 kgf range, while forces at or below 1 kgf may also require consideration of ASTM E384. ASTM E92 information
Important Limitation
The minimum force is 1 kgf. Very thin coatings, microscopic phases or shallow case-depth traverses may require a lower-force micro-Vickers tester.
Applications
- Heat-treatment verification
- Hardened and tempered steels
- Tool steels and alloy steels
- Stainless steel and non-ferrous metals
- Carburized, nitrided and induction-hardened layers
- Case-depth profiles on prepared cross-sections
- Welds and heat-affected zones
- Fasteners, gears, shafts and bearings
- Cutting tools and dies
- Small precision components
- Suitable metallic coatings and deposited layers
- Metallurgical laboratories
- Production quality control
- Research and failure-analysis support
What's Included
✓ QE-DVH50 digital Vickers hardness tester
✓ Vickers diamond pyramid indenter
✓ Digital measuring eyepiece
✓ 100×/200× optical system
✓ Large flat anvil
✓ Small flat anvil
✓ V-shaped anvil
✓ Certified reference-block set identified in the quotation
✓ Standard accessory and tool kit
✓ Levelling feet
✓ Dust cover
✓ 110 V, 60 Hz power cord
✓ Operating manual
✓ Factory test certificate
✓ QMN certificate of conformity
✓ 12-month warranty
Downloads
Brochure
QE-DVH50 Digital Macro-Vickers Hardness Tester
Why Choose This Model?
- Nine selectable test forces from 1 to 50 kgf
- Automatic loading, dwell and unloading
- Direct digital calculation of Vickers hardness
- 100× observation and 200× measurement
- Adjustable dwell time
- Digital measuring eyepiece
- Rigid laboratory bench configuration
- Manual turret for straightforward operation
Need help selecting the right configuration?
Our application specialists are here to help you choosing the best solution for your materials and workflow.
Talk to an expert
Get expert advice on models, accessories and standards.
- 647-948-7714
- info@qmnequipment.com
- Mon-Friday: 9:00am to 6:00pm ET
Frequently Asked Questions
What is the maximum test force of the QE-DVH50?
The maximum test force is 50 kgf, corresponding to an HV50 Vickers test.
What is the minimum test force?
The standard configuration begins at 1 kgf, corresponding to HV1.
Is this a microhardness tester?
The QE-DVH50 can perform selected low-force Vickers tests beginning at HV1. Applications requiring forces below 1 kgf—such as very thin coatings, microscopic phases or shallow hardness gradients—require a dedicated microhardness tester.
Does the machine apply the test force automatically?
Yes. Loading, dwell and unloading are performed automatically after the test cycle is started.
Is indentation measurement fully automatic?
No. The standard configuration uses a digital measuring eyepiece. The operator aligns the measuring lines with the two indentation diagonals, and the instrument calculates the Vickers hardness result.
Why Buy From QMN Equipment?
Equipment selected by testing professionals. Backed by CMH MetLabs expertise in:

Hardness Testing
Brinell, Rockwell and Vickers and more

Tensile Testing
Universal Testing Machines

Metallography
Sample Preparation and Analysis

NDT Inspection
UT, PT, MT, RT Solutions

Failure Analysis
Expert Analysis and Reporting

Backed by CMH Metlabs
Accredited by
Our in-house laboratory ensures you get the right equipment.